Dissolved Oxygen Sensor
KODO Series
Technical Specifications

Fluid: Liquid

Range: 0…20 mg/L (optional 0…40 mg/L)

Communication (Comm.): 4–20 mA, RS485 Modbus

Temperature: 70°C (optional 130°C)

Pressure: 1 bar (optional 7 bar)

Connection: 3/4” NPT / PG 13.5

Enclosure: IP68

Body: Stainless steel (SS), PP, AISI 316

Method: Optical fluorescence (luminescence) measurement method

Kanagawa Instruments KODO Series Dissolved Oxygen Sensors

Kanagawa Instruments KODO Series Dissolved Oxygen Sensors are advanced industrial analysis solutions developed to measure dissolved oxygen (DO – Dissolved Oxygen) levels in liquids with high accuracy. They perform critical DO measurements reliably, quickly, and with low maintenance requirements in water treatment, aquaculture, and process control applications.

In water quality management, dissolved oxygen level is one of the most important parameters in terms of both the sustainability of biological life and process efficiency. KODO Series sensors continuously and accurately provide this critical data, enabling businesses to optimize their performance.


Advanced Dissolved Oxygen Measurement Technology

The KODO Series measures oxygen gas dissolved in liquids and provides output in mg/L, ppm, or % saturation.

  • High-accuracy DO measurement

  • Fast response time (< 60 seconds)

  • Automatic temperature compensation

  • Stable and repeatable measurement results

This enables reliable data to be obtained in both environmental monitoring and industrial processes.


Optical and Electrochemical Sensor Technologies

The KODO Series supports two different measurement technologies suitable for different application requirements:

Optical (Luminescent) Sensors

It is a modern and advanced measurement method.

Operating principle:

  • LED light is directed onto the sensor surface

  • The luminophore layer emits light

  • Oxygen quenches this light (quenching effect)

  • The change in light is correlated with the DO level

Advantages:

  • Low calibration requirements

  • No electrolyte or membrane required

  • High stability

  • Long sensor life

  • Minimal influence from chemical effects


Electrochemical Sensors

It is a classic and widely used method.

Operating principle:

  • Oxygen diffuses through the membrane

  • A reaction takes place at the electrode surface

  • The resulting current is proportional to the DO concentration

Advantages:

  • Economical solution

  • Wide range of applications


Superior Measurement Stability and Reliability

KODO sensors provide high performance even under variable process conditions:

  • Low drift

  • Stable signal output

  • High repeatability

  • Fast adaptation to dynamic processes

Thanks to these features, they can be used reliably, especially in systems requiring precise control.


Critical Importance of Dissolved Oxygen

Dissolved oxygen directly affects the biological and chemical structure of water.

Critical levels:

  • < 5 mg/L → Risky level

  • < 2 mg/L → Critical level

Therefore, DO levels must be continuously monitored.

Importance:
  • Sustainability of aquatic life

  • Efficiency of biological treatment processes

  • Control of fermentation and production processes

  • Detection of water pollution


Adaptation to Environmental and Process Factors

KODO sensors adapt to variables affecting dissolved oxygen levels:

  • Temperature changes (automatic compensation)

  • Pressure effects

  • Salinity changes

  • Biological activity intensity

  • Fluid movement and turbulence

This ensures accurate measurement under different environmental conditions.


Technical Specifications
  • Measurement range: 0 – 20 mg/L (expandable)

  • Response time: < 60 seconds

  • Output: 4–20 mA and digital communication

  • Temperature compensation: Automatic

  • Protection class: IP68

  • Body: Industrial-duty construction


Low Maintenance and Long Service Life Advantages

KODO Series sensors stand out with their minimum maintenance requirements:

  • No consumables in optical models

  • Long calibration intervals

  • Easy cleaning and maintenance

  • Durable construction for harsh environments

These features significantly reduce operating costs.


Wide Range of Applications

KODO Dissolved Oxygen Sensors play a critical role in many industries:

Water and Wastewater Treatment
  • Aeration control

  • Biological process optimization

Aquaculture
  • Fish health monitoring

  • Oxygen level balancing

Drinking Water Systems
  • Water quality monitoring

Food and Beverage Industry
  • Fermentation processes

  • Product quality control

Energy and Industry
  • Boiler water monitoring

  • Corrosion control

Environmental Monitoring
  • River, lake, and seawater analysis

  • Ecosystem health assessment


Easy Integration and System Compatibility

KODO Series sensors are fully compatible with modern automation systems:

  • 4–20 mA analog output

  • Integration with PLC and SCADA systems

  • Digital communication support

This allows easy integration into existing infrastructure.


Calibration and Maintenance
Calibration
  • Air calibration

  • Verification with standard solutions

Maintenance
  • Sensor surface cleaning

  • Protective cap inspection

  • Periodic performance verification

With regular maintenance, high accuracy can be maintained for a long period.


Competitive Advantages

The KODO Series offers features capable of competing with many solutions on the market:

  • High accuracy and stability

  • Low maintenance cost

  • Optical and electrochemical options

  • Flexible use and wide range of applications

  • Industrial durability


Future-Ready Sensor Technology

With Industry 4.0, KODO sensors are designed to be compatible with advanced features such as:

  • IoT integration

  • Remote monitoring

  • Predictive maintenance


Why Kanagawa Instruments KODO Series?
  • High-accuracy dissolved oxygen measurement

  • Optical and electrochemical sensor options

  • Low maintenance and long service life

  • Fast response time

  • Resistance to harsh process conditions

  • Automatic temperature compensation

  • Easy integration with industrial systems


In conclusion, Kanagawa Instruments KODO Series Dissolved Oxygen Sensors provide high precision, reliability, and sustainable performance in water quality monitoring and process control applications. In processes where even small changes in DO can have significant effects, they increase operational efficiency and strengthen environmental control by providing accurate and continuous measurement.