Dissolved Oxygen Sensor
KODO Series
Technical Specifications
Fluid: Liquid
Range: 0…20 mg/L (optional 0…40 mg/L)
Communication (Comm.): 4–20 mA, RS485 Modbus
Temperature: 70°C (optional 130°C)
Pressure: 1 bar (optional 7 bar)
Connection: 3/4” NPT / PG 13.5
Enclosure: IP68
Body: Stainless steel (SS), PP, AISI 316
Method: Optical fluorescence (luminescence) measurement method
Kanagawa Instruments KODO Series Dissolved Oxygen Sensors
Kanagawa Instruments KODO Series Dissolved Oxygen Sensors are advanced industrial analysis solutions developed to measure dissolved oxygen (DO – Dissolved Oxygen) levels in liquids with high accuracy. They perform critical DO measurements reliably, quickly, and with low maintenance requirements in water treatment, aquaculture, and process control applications.
In water quality management, dissolved oxygen level is one of the most important parameters in terms of both the sustainability of biological life and process efficiency. KODO Series sensors continuously and accurately provide this critical data, enabling businesses to optimize their performance.
Advanced Dissolved Oxygen Measurement Technology
The KODO Series measures oxygen gas dissolved in liquids and provides output in mg/L, ppm, or % saturation.
High-accuracy DO measurement
Fast response time (< 60 seconds)
Automatic temperature compensation
Stable and repeatable measurement results
This enables reliable data to be obtained in both environmental monitoring and industrial processes.
Optical and Electrochemical Sensor Technologies
The KODO Series supports two different measurement technologies suitable for different application requirements:
Optical (Luminescent) Sensors
It is a modern and advanced measurement method.
Operating principle:
LED light is directed onto the sensor surface
The luminophore layer emits light
Oxygen quenches this light (quenching effect)
The change in light is correlated with the DO level
Advantages:
Low calibration requirements
No electrolyte or membrane required
High stability
Long sensor life
Minimal influence from chemical effects
Electrochemical Sensors
It is a classic and widely used method.
Operating principle:
Oxygen diffuses through the membrane
A reaction takes place at the electrode surface
The resulting current is proportional to the DO concentration
Advantages:
Economical solution
Wide range of applications
Superior Measurement Stability and Reliability
KODO sensors provide high performance even under variable process conditions:
Low drift
Stable signal output
High repeatability
Fast adaptation to dynamic processes
Thanks to these features, they can be used reliably, especially in systems requiring precise control.
Critical Importance of Dissolved Oxygen
Dissolved oxygen directly affects the biological and chemical structure of water.
Critical levels:
< 5 mg/L → Risky level
< 2 mg/L → Critical level
Therefore, DO levels must be continuously monitored.
Importance:
Sustainability of aquatic life
Efficiency of biological treatment processes
Control of fermentation and production processes
Detection of water pollution
Adaptation to Environmental and Process Factors
KODO sensors adapt to variables affecting dissolved oxygen levels:
Temperature changes (automatic compensation)
Pressure effects
Salinity changes
Biological activity intensity
Fluid movement and turbulence
This ensures accurate measurement under different environmental conditions.
Technical Specifications
Measurement range: 0 – 20 mg/L (expandable)
Response time: < 60 seconds
Output: 4–20 mA and digital communication
Temperature compensation: Automatic
Protection class: IP68
Body: Industrial-duty construction
Low Maintenance and Long Service Life Advantages
KODO Series sensors stand out with their minimum maintenance requirements:
No consumables in optical models
Long calibration intervals
Easy cleaning and maintenance
Durable construction for harsh environments
These features significantly reduce operating costs.
Wide Range of Applications
KODO Dissolved Oxygen Sensors play a critical role in many industries:
Water and Wastewater Treatment
Aeration control
Biological process optimization
Aquaculture
Fish health monitoring
Oxygen level balancing
Drinking Water Systems
Water quality monitoring
Food and Beverage Industry
Fermentation processes
Product quality control
Energy and Industry
Boiler water monitoring
Corrosion control
Environmental Monitoring
River, lake, and seawater analysis
Ecosystem health assessment
Easy Integration and System Compatibility
KODO Series sensors are fully compatible with modern automation systems:
4–20 mA analog output
Integration with PLC and SCADA systems
Digital communication support
This allows easy integration into existing infrastructure.
Calibration and Maintenance
Calibration
Air calibration
Verification with standard solutions
Maintenance
Sensor surface cleaning
Protective cap inspection
Periodic performance verification
With regular maintenance, high accuracy can be maintained for a long period.
Competitive Advantages
The KODO Series offers features capable of competing with many solutions on the market:
High accuracy and stability
Low maintenance cost
Optical and electrochemical options
Flexible use and wide range of applications
Industrial durability
Future-Ready Sensor Technology
With Industry 4.0, KODO sensors are designed to be compatible with advanced features such as:
IoT integration
Remote monitoring
Predictive maintenance
Why Kanagawa Instruments KODO Series?
High-accuracy dissolved oxygen measurement
Optical and electrochemical sensor options
Low maintenance and long service life
Fast response time
Resistance to harsh process conditions
Automatic temperature compensation
Easy integration with industrial systems
In conclusion, Kanagawa Instruments KODO Series Dissolved Oxygen Sensors provide high precision, reliability, and sustainable performance in water quality monitoring and process control applications. In processes where even small changes in DO can have significant effects, they increase operational efficiency and strengthen environmental control by providing accurate and continuous measurement.