Ultrasonic / Open Channel Flow Meter – KOCF Series
Technical Specifications
Fluid: Liquid
Range: 0–6 m … 0–10 m
Power Supply: 24 VDC (Optional: 230 VAC)
Communication: RS-485 Modbus, HART, PROFIBUS
Accuracy: < ±2 mm
Connection: Channels, Flume Systems / Standard Channels
Protection Class: IP65 Display, IP67 Sensor
Output: Pulse, 4–20 mA
Display: Flow Rate, Total Volume, and Level TFT Display
Kanagawa Instruments Ultrasonic Open Channel Flow Meters – KOCF Series
Kanagawa Instruments KOCF Series Ultrasonic Open Channel Flow Meters are professional ultrasonic flow measurement systems developed for accurate flow measurement in open channels, weir systems, Parshall flume applications, and partially filled pipes. Thanks to non-contact ultrasonic measurement technology, they provide high-accuracy measurement of liquid level, instantaneous flow rate, and total volume values, enabling continuous process monitoring.
The KOCF Series provides reliable performance in wastewater treatment plants, industrial discharge lines, irrigation channels, environmental monitoring systems, sewer infrastructure, and hydraulic processes. Since the sensor does not come into contact with the liquid, maintenance requirements are minimized while long-term stable measurement performance is achieved.
Advanced Ultrasonic Measurement Technology
Kanagawa Instruments KOCF Series operates with the ultrasonic time-of-flight measurement principle. High-frequency ultrasonic waves transmitted by the sensor reflect from the liquid surface and return to the sensor. The liquid level is determined with high accuracy by calculating the travel time of the ultrasonic waves.
With this system:
Non-contact level measurement
Real-time flow calculation
Total volume measurement
Continuous process monitoring
Low maintenance requirement
are provided.
The measured level information is evaluated with channel geometry and hydraulic calculation algorithms to automatically calculate the flow rate.
Advanced Flow Calculation Algorithms
The KOCF Series supports advanced flow calculation models suitable for different channel and weir structures.
Supported calculation methods:
Manning equation
V-notch weir calculations
Rectangular weir calculations
Broad-crested weir curves
Parshall flume flow curves
Venturi flume calculations
Thanks to these advanced algorithms, high measurement accuracy is achieved in different hydraulic structures.
Minimum Maintenance with Non-Contact Measurement
One of the most important advantages of the KOCF Series is that the sensor does not come into contact with the liquid.
Thanks to this design:
No corrosion risk occurs
Fouling is minimized
Sensor clogging is prevented
Maintenance costs are reduced
Long service life is achieved
Non-contact measurement technology provides significant advantages especially in dirty, abrasive, or particle-containing fluids.
High Measurement Accuracy and Stable Performance
Kanagawa Instruments KOCF Series provides high accuracy across a wide measurement range.
Key performance features:
Accuracy up to ±0.25%
Level accuracy of ±2 mm
Stable measurement performance
Real-time data generation
Wide measurement distance
This structure provides reliable results in both low-flow and high-flow applications.
Pressure Loss-Free Design
The KOCF Series operates without placing any mechanical equipment inside the flow.
This advantage provides:
No hydraulic losses
No disturbance to flow characteristics
Maintained system efficiency
Prevention of energy losses
This feature provides significant advantages especially in large open channel systems.
Wide Application Compatibility
The KOCF Series is designed for use with different channel and flow structures.
Supported applications:
Open concrete channels
Weir systems
V-notch weirs
Rectangular weirs
Broad-crested weirs
Parshall flume systems
Venturi flume structures
Partially filled pipes
Thanks to this flexible structure, it can be used in a wide range of industrial and environmental applications.
Advanced Data Logging and Communication Features
Kanagawa Instruments KOCF Series features advanced data management infrastructure.
Standard features:
Internal data logger with capacity of 26 million data points
USB data transfer
4–20 mA analog output
Relay outputs
Digital communication support
Modbus RTU communication
Modbus TCP support
With optional communication options:
Ethernet connection
WiFi integration
Remote data access
SCADA connection
are possible.
This structure enables easy integration with Industry 4.0 and modern automation systems.
Smart Control and Alarm Functions
The KOCF Series does not only perform measurement but also plays an active role in process control applications.
Supported control features:
Programmable relay outputs
Level alarm
Flow alarm
Pump control
Automatic process management
These features provide significant advantages especially in wastewater plants and channel management systems.
Doppler Technology for Velocity + Level Measurement
The KOCF Series optionally supports velocity + level measurement systems operating with the Doppler principle.
In these systems:
Velocity measurement is performed through particles within the flow
The sensor is directly installed into the flow
Flow rate is calculated using the velocity × cross-sectional area method
Advantages of Doppler technology:
High accuracy at low levels
Reliable performance in dirty fluids
Stable measurement in particle-containing flows
No need for an additional level sensor
This structure is especially preferred for heavily contaminated wastewater applications.
Technical Specifications
Electronic Unit
Protection Class: IP66 / NEMA4X
Operating Temperature: -20°C … +60°C
Power Supply:
100–240 VAC
10–36 VDC
Outputs:
4–20 mA
Relay
Digital communication
Ultrasonic Sensor
Measurement Distance: 4.5 m – 10 m
Frequency:
42 kHz
92 kHz
Beam Angle: 8°
Sensor Material:
PVC
Teflon
Features:
Automatic temperature compensation
Easy Installation and Low Operating Cost
The KOCF Series provides fast installation advantages.
Installation advantages:
Sensor mounted above the channel
No additional mechanical structure required
Fast commissioning
Low installation cost
Maintenance advantages:
No moving parts
Minimum maintenance requirement
Long sensor lifetime
Low operating cost
This structure significantly reduces the total cost of ownership.
Wide Range of Applications
Wastewater Treatment Plants
The KOCF Series is widely used for:
Inlet flow measurement
Outlet flow monitoring
Environmental reporting
Process optimization
Industrial Discharge Systems
Preferred for factory wastewater management:
Discharge control
Regulatory reporting
Chemical process monitoring
Stormwater and Sewer Lines
Used in urban infrastructure systems for:
Flood control
Channel monitoring
Continuous flow measurement
Remote monitoring
Agriculture and Irrigation Systems
Provides:
Water management
Efficient resource utilization
Flow optimization
in irrigation channels.
Environmental Monitoring
Provides reliable data for:
River flow measurement
Stream monitoring
Hydrological analysis
Ecosystem monitoring
SCADA and Industry 4.0 Integration
The KOCF Series is fully compatible with modern automation systems.
Integration options:
SCADA systems
PLC automation
Remote telemetry systems
Ethernet infrastructures
Cloud-based data monitoring
This enables users to access real-time data remotely.
Why Kanagawa Instruments KOCF Series?
Non-contact ultrasonic measurement technology
Suitable design for open channel and weir applications
Parshall flume support
High measurement accuracy
Minimum maintenance requirement
Wide communication options
SCADA and PLC integration
Powerful data logging infrastructure
Low operating cost
Industrial durability
Long service life
Kanagawa Instruments KOCF Series Ultrasonic Open Channel Flow Meters are professional flow measurement systems providing high accuracy, reliability, and long-term field performance in open channel flow measurement applications. With advanced ultrasonic measurement technology, powerful communication infrastructure, and flexible application options, they provide reliable solutions across a wide range of applications from wastewater management to environmental monitoring.